BJXKF - FILLER, WOOD, PLASTIC, X-532

  • MSDS: BJXKF
  • Manufacturer: BAKER SEALANTS AND COATINGS
  • Product Name: FILLER, WOOD, PLASTIC, X-532
  • National Stock Number: 8010-00-262-9171
Product Identification

Product ID:FILLER, WOOD, PLASTIC, X-532
MSDS Date:10/17/1989
FSC:8010
NIIN:00-262-9171
MSDS Number: BJXKF

Responsible Party
BAKER SEALANTS & COATINGS
234 SUYDAM AVENUE
JERSEY CITY, NJ 07304
US

Emergency Phone: 800-424-9300

Info Phone: 800-424-9300

Cage: FO833

Contractor
BAKER SEALANTS AND COATINGS CO
JERSEY CITY, NJ 07304-3306 US

Telephone: 201-333-6986

Cage: 34094

Ingredients

ISOPROPYL ALCOHOL (SARA III)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 6-8%

OSHA PEL 400 PPM/500 STEL

ACGIH TLV: 400 PPM/500STEL;9192


ACETONE (SARA III)

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 19-22%

OSHA PEL 1000PPM

ACGIH TLV: 750PPM/1000STEL;9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 25-35%

OSHA PEL 200 PPM/300 STEL

ACGIH TLV: 200 PPM/300STEL 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:METHTL ETHYL KETONE BY ITSELF HAS NOT
BEEN SHOWN TO CAUSE PERIPHERAL NEUROPATHY. OVEREXPOSURE TO THIS
MATERIAL HAS APPARENTLY BEEN FOUND TO CAUSE THE FOLLOWING EFFECTS
IN LABORATORY ANIMALS: LIVER ABN ORMALITIES, KIDNEY DAMAGE, LUNG
DAMAGE,AND BRAIN DAMAGE.
Effects of Overexposure:EYES:SEVERLY IRRIT.WILL INJURE EYE TISSUE,MAY
RESULT IN PERM DAMAGE.SKIN:IRRITATE &
DERMATITIS.INHALATION:IRRITATING TO EYES AND RESPIRATORY
TRACT.CAUSE HEADACHES,DIZZINESS,ARE ANESTHETIC & MAY HAVE O THER
CENTRAL NERVOUS SYSTEM EFFECTS.INGESTION.MAY CAUSE
BRONCHIOPNEUMONIA OR PULMONARY EDEMA BY ASPIRATION OF LIQUID.
Medical Cond Aggravated by Exposure:MINOR EMBROYTOXIC/FETOTOXIC EFFECTS
HAVE BEEN OBSERVED IN LABORATORY RATS.

First Aid

First Aid:EYES:IMMEDIATELY FLUSH WITH LARGE AMOUNTS OF WATER FOR 15
MIN.GET MEDICAL ATTENTION.SKIN:IMMEDIATELY WASH WITH LARGE AMOUNTS
OF WATER.USE SOAP IF AVAILABLE.INHALATION:IMMEDIATELY REMOVE VICTIM
FROM EX POSURE.ADMINISTER ARTIFICIAL RESPIRATION IF BREATHING IS
STOPPED.KEEP AT REST.GET MEDICAL ATTENTION.INGESTION:DO NOT INDUCE
VOMITING.KEEP AT REST.GET PROMPT MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:TOC
Flash Point:4F/-15.6C
Autoignition Temp:Autoignition Temp Text:NIF
Lower Limits:3.6
Upper Limits:12.8
Extinguishing Media:EXTINGUISH WITH ALCOHOL FOAM, CARBON DIOXIDE FOAM.
Fire Fighting Procedures:AVOID UNNECESSARY EXPOSURE TO HEAT.
Unusual Fire/Explosion Hazard:DO NOT ALLOW MATERIAL TO BECOME DRY.
MATERIAL BURNS RAPIDLY WITH INTENSE HEAT.

Accidental Release

Spill Release Procedures:FLUSH WITH WATER. DO NOT ALLOW TO DRY. DIKE
AREA. SHOVEL INTO CONTAINERS.

Handling

Handling and Storage Precautions:GROUND ALL MIXING TANKS AND DRUMS.
STORE IN COOL AREA.

Exposure Controls

Respiratory Protection:SELF-CONTAINED BREATHING APPARATUS.
Ventilation:MECHANICAL-EXPLOSION PROOF MOTORS AND SWITCHES.
Protective Gloves:RUBBER GLOVES
Eye Protection:GOGGLES
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:175F/79.4C
Melt/Freeze Pt:M.P/F.P Text:<32F/<0C
Decomp Temp:Decomp Text:NIF
Vapor Pres:70 @ 68F
Vapor Density:2.5
Spec Gravity:0.81
pH:7.0
Evaporation Rate & Reference:7.0
Solubility in Water:SLIGHT
Appearance and Odor:VISCOUS SOLUTION ODOR KEYTONIC
Percent Volatiles by Volume:80

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HIGH HEAT

Disposal

Waste Disposal Methods:AS PER LOCAL, STATE OR FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.